The Standard Digital Protectowire Heat Sensitive Cable (PHSC) linear heat detector can best be described as a continuous run of spot heat detectors. It is capable of sensing heat anywhere along its length and initiates an alarm once its fixed activation temperature is reached.
Protectowire Linear Heat Detector is a proprietary cable that detects heat anywhere along its length. The sensor cable is comprised of two steel conductors individually insulated with a heat sensitive polymer. The insulated conductors are twisted together to impose a spring pressure between them, then wrapped with a protective tape and finished with an outer jacket suitable for the environment in which the detector will be installed. Protectowire is a fixed temperature digital sensor and is therefore capable of initiating an alarm once its rated activation temperature is reached. At the rated temperature, the heat sensitive polymer insulation yields to the pressure upon it, permitting the inner conductors to move into contact with each other thereby initiating an alarm signal. This action takes place at the first heated point anywhere along the detector’s length. It does not require a specific length to be heated in order to initiate an alarm, nor system calibration to compensate for changes in the installed ambient temperature. Protectowire Linear Heat Detector provides the advantages of line coverage with point sensitivity
Features
Applications
Linear Heat Detectors are particularly suitable in extremely dangerous environmental conditions such as in the presence of corrosive elements or condensing steams.
Ideally suited to industrial high risk hazards as well as many types of commercial applications, Protectowire Linear Heat Detector has unique advantages over other types of detectors, especially when difficult installation factors or severe environmental conditions are present. When used with the appropriate Protectowire control equipment, the detector will activate a display, showing the location of an over heat or fire condition anywhere along its length.
Protectowire LHD
The Protectowire family of Confirmed Temperature Initiation Linear Heat Detectors are advanced multi-sensor detectors consisting of models with alarm temperatures ranging from 135°F (57°C) to 356°F (180°C). Each detector is comprised of two special metallic alloy conductors individually insulated with a heat sensitive polymer. The insulated conductors are twisted together to impose a spring pressure between them, then wrapped with a protective tape and finished with a durable f lame retardant outer jacket. The detectors are fixed temperature digital sensors that are capable of initiating an alarm signal. Once exposed to the rated temperature the heat sensitive polymer yields to the inherent spring tension allowing the conductors to move into contact with each other, thereby creating a short circuit temperature measuring junction point. A CTM Module is required to supervise all CTI Linear Heat Detectors. The CTM interface module is designed to detect a short circuit and enter a heat measuring thermocouple mode.
By entering the thermocouple mode, the interface module is able to identify the temperature at the short and determine the type of off-normal condition being created based upon the alarm temperature threshold of the detector. If the interface module determines that the temperature at the short is above the predetermined alarm threshold temperature, the module initiates an ALARM condition and displays the location of the alarm if equipped with the Protectowire Alarm Point Location Meter. If, however, the interface module determines the temperature is below the alarm temperature threshold, it initiates a short circuit fault or TROUBLE condition and displays its location on the Protectowire Alarm Point Location Meter (if provided) so it can be corrected. The Protectowire advanced multi-sensor detectors are the first digital type linear heat detectors to provide true confirmed temperature initiation and mechanical short circuit discrimination. They provide reliable temperature response with verified alarm temperature confirmation for exceptional false alarm immunity
Features
Applications
Linear Heat Detectors are particularly suitable in extremely dangerous environmental conditions such as in the presence of corrosive elements or condensing steams.
Ideally suited to industrial high risk hazards as well as many types of commercial applications, Protectowire Linear Heat Detector has unique advantages over other types of detectors, especially when difficult installation factors or severe environmental conditions are present. When used with the appropriate Protectowire control equipment, the detector will activate a display, showing the location of an over heat or fire condition anywhere along its length.
Protectowire LHD
Click on the links below to download the Datasheets of the Protectowire LHD or view their website at: www.protectowire.com
This website uses cookies. By continuing to use this site, you accept our use of cookies. Privacy Policy